Mon Nov 12 08:20:57 EST 2007 Input file [ heatxchngrUS.txt ] #----------------------Input---------------------# mdothot 3600.0 (lbm / hr) Cphot 1.00 (BTU / lbm / F) Thotin 200 (deg F) Thotout 150 (deg F) mdotcool 3600.0 (lbm / hr) Cpcool 1.00 (BTU / lbm / F) Tcoolin 25 (deg F) Tcoolout 50 (deg F) Type 2 (1 = parallel; 2 = Counterflow) #-----------------Output--------------------# Qhot= -180000 BTU/hr Qcool= 90000 BTU/hr Qhot+Qcool must = zero or following calcs are wrong Counter-flow x-chngr, Thotout must be > Tcoolin Overall U is the overall heat transfer coefficient of the design (BTU/hr/sqft/F). A is the effective heat transfer area of the design (sqft). UA and Qcheck shown below is based on coolside flow. LMTD = 137.12 F Overall U * Area = 656.36 BTU/hr/F Qcheck = 90000.00 BTU/hr #.......................End of File..............#